09:23:30 From SAULO ADAMI LOUREIRO to Everyone: SIM 09:23:34 From giuseppe jango brustulin to Everyone: sim 09:23:36 From Gabriel Assis to Everyone: sim 09:23:45 From Wagner Camargo Goes to Everyone: Sim 09:24:22 From Alexandre Coêlho to Everyone: sim 09:24:36 From Amsterdam Mendonça to Everyone: Vou tentar agora eu, então, reiniciar. Agora não ouço ninguém... 09:24:48 From Sociedade Brasileira de Metrologia SBM to Everyone: Professor 09:24:56 From Flavia Almeida to Everyone: sim 09:25:00 From Sociedade Brasileira de Metrologia SBM to Everyone: Estamos ouvindo! 09:25:00 From Gabriel Assis to Everyone: sim 09:27:11 From Amsterdam Mendonça to Everyone: Agora consegui! Muito obrigado a todos! 09:28:31 From Sociedade Brasileira de Metrologia SBM to Everyone: Boa aula! 09:32:31 From Flavia Almeida to Everyone: Bom dia. Não tenho áudio, vou escrever aqui. Estamos começando a implementar a calibração de termômetros e decidimos fazer o curso para entendermos mais sobre o assunto, tanto a parte prática quanto a parte teórica. 09:32:50 From Flavia Almeida to Everyone: estamos em grupo também o pessoal da Casa Offshore 09:32:55 From Flavia Almeida to Everyone: Flavia e Gabriel 09:33:50 From Jean Patricio to Everyone: Bom dia, não possuo aúdio, o meu objetivo desse curso é me aprofundar na parte de calibração de termometros, já realizei pela SBM o curso de incerteza de medição e analise critica de certificados 09:33:51 From giuseppe jango brustulin to Everyone: bom dia 09:34:04 From giuseppe jango brustulin to Everyone: estou sem audio 09:34:30 From giuseppe jango brustulin to Everyone: trabalho como técnico de instrumentação 09:34:32 From Jean Patricio to Everyone: estou sem áudio tbm, como disse no chat 09:35:03 From giuseppe jango brustulin to Everyone: em toledo Parana 09:35:16 From SAULO ADAMI LOUREIRO to Everyone: SIM. 09:35:20 From SAULO ADAMI LOUREIRO to Everyone: SIM 09:35:38 From SAULO ADAMI LOUREIRO to Everyone: Estou sem microfone. 10:22:56 From Gabriel Assis to Everyone: há diferença se fizermos a medição da temperatura na calibração em ciclos, aumentando e depois diminuindo a temperatura? 10:25:14 From Gabriel Assis to Everyone: no certificado é necessário demonstrar a histerese? 10:27:40 From Gabriel Assis to Everyone: o nosso termômetro padrão deve ser quantas vezes melhor que o termômetro a ser calibrado? 10:29:05 From Prof Alexandre Mendes to Everyone: resolução = 0,1 °C 10:29:19 From Prof Alexandre Mendes to Everyone: U = 0,1/0,2/0,3 10:58:13 From Carlos Souza to Everyone: sim 10:58:19 From Wagner Camargo Goes to Everyone: Perfeitamente 10:58:20 From giuseppe jango brustulin to Everyone: sim 11:36:29 From Prof Alexandre Mendes to Everyone: 38 +/- 1 11:36:40 From Prof Alexandre Mendes to Everyone: 37 A 39 11:43:20 From Prof Alexandre Mendes to Everyone: X1 11:43:22 From Prof Alexandre Mendes to Everyone: X2 11:43:24 From Prof Alexandre Mendes to Everyone: X3 11:43:26 From Prof Alexandre Mendes to Everyone: X4 11:43:35 From Prof Alexandre Mendes to Everyone: MEDIA DAS MEDIAS 11:43:46 From Prof Alexandre Mendes to Everyone: DESVIO PADRÃO DAS MEDIAS? 11:44:25 From Prof Alexandre Mendes to Everyone: DESVIO PADRÃO X1/RAIZ(N) 11:45:58 From Prof Alexandre Mendes to Everyone: 20 °C 11:46:08 From Prof Alexandre Mendes to Everyone: x1 = 20 11:46:13 From Prof Alexandre Mendes to Everyone: x2 = 21 11:46:18 From Prof Alexandre Mendes to Everyone: x3 = 19 11:46:28 From Prof Alexandre Mendes to Everyone: media = 20 11:46:38 From Prof Alexandre Mendes to Everyone: s = 1 11:47:30 From Prof Alexandre Mendes to Everyone: desvio padrão da media = 1/raiz(3) 13:11:57 From Prof Alexandre Mendes to Everyone: GL = numero de possibilidades - numero de restrições 13:12:29 From Prof Alexandre Mendes to Everyone: 3 medições, cuja media é 4 13:13:43 From Prof Alexandre Mendes to Everyone: x1 = 6 13:13:52 From Prof Alexandre Mendes to Everyone: x2=4 13:13:58 From Prof Alexandre Mendes to Everyone: x3=???? 13:14:46 From Prof Alexandre Mendes to Everyone: x3 = 2 13:14:56 From Prof Alexandre Mendes to Everyone: 2+4+6)/3 = 4 13:23:02 From Wagner Camargo Goes to Everyone: Professor, se for a primeira calibração do padrão, o que poderia considerar na deriva? 13:31:43 From Flavia Almeida to Everyone: e se for um valor q não estiver na tabela. por exemplo 2,095? 13:31:50 From Flavia Almeida to Everyone: faz uma interpolação? 14:02:07 From Prof Alexandre Mendes to Everyone: Ecil 14:02:10 From Prof Alexandre Mendes to Everyone: Fluke 14:02:13 From Prof Alexandre Mendes to Everyone: Presys 14:05:01 From Gabriel Assis to Everyone: nas condições ambientais o mais indicado é colocar o valor corrigido, ou colocar a faixa de variação das medições como está nesse certificado? 14:10:10 From Flavia Almeida to Everyone: nesse caso o multímetro entra como fonte de incerteza? 14:23:40 From Wagner Camargo Goes to Everyone: Professor, em relação a fórmula do excel para o coeficiente angular fiquei na dúvida se seria nessa posição, =inclinação(referência_y;objeto_x) 14:25:39 From Wagner Camargo Goes to Everyone: Muito obrigado Professor, entendido. 14:29:20 From Flavia Almeida to Everyone: então o GL sempre vai ser a quantidade de pontos de calibração -2 14:34:26 From Gabriel Assis to Everyone: o maior é o primeiro 16:17:44 From Wagner Camargo Goes to Everyone: Professor, se no caso for utilizado apenas um diâmetro, por exemplo 6mm, poderia apenas fazer a rotação do bloco seco? 16:19:05 From Wagner Camargo Goes to Everyone: Positivo 16:23:43 From Wagner Camargo Goes to Everyone: Obrigado professor! 16:38:23 From giuseppe jango brustulin to Everyone: sempre realizo a verificação intermediaria em ponto do gelo, a cada 3 mês, utilizado a garrafa termica 17:07:54 From Alexandre Coêlho to Everyone: O cappo geral também 17:08:32 From Alexandre Coêlho to Everyone: aqui utilizamos o cappo, é muito bom para trabalho em campo 17:30:39 From Wagner Camargo Goes to Everyone: Boa tarde 17:30:40 From Gabriel Assis to Everyone: obrigada